Sign In | Join Free | My portofva.com
China Wuhan Rising Electric Co., Ltd. logo
Wuhan Rising Electric Co., Ltd.
Active Member

6 Years

Home > Transformer Testing Equipment >

CE Hand Held Voltammeter Double Clamp Digital Phase Meter

Wuhan Rising Electric Co., Ltd.
Contact Now

CE Hand Held Voltammeter Double Clamp Digital Phase Meter

Brand Name : RISING

Model Number : RS2000E

Certification : ISO CE

Place of Origin : China

MOQ : 1

Supply Ability : 500 SET PER Month

Delivery Time : 5-8 days

Packaging Details : Wooden package for export

Phase : Single Phase

Accuracy Class : ±(0.3%RD+0.2% Range)

Output Voltage : 30V~500V

Dimensions : 192*95*55mm3

Display : three and half

Sampling rate : 3 times per second

Contact Now

RS2000E Double Clamp Digital Voltammeter Phase Tester

Product Description

RS20000E Double Clamp Digital Phase Meter is special designed for testing voltage, current and phase onsite, it is in high-precision, low price, portable hand-held, dual-channel input measuring products. It’s easy to measure the phase between U-U, I-I and U-I, identify the inductive circuit ,capacitive circuit and the phase sequence of three-phase voltage, detect the wiring group of transformer, test the secondary circuit and bus differential protection system, read the phase relationship among the CT groups of a differential protection system, and check if the watthour meter was correctly wired. When testing customers do not need cut off the measured circuit which input by split core current transformer. When measuring the phase between U1 and U2, the two input circuit loop are completely insulated isolation, so the possibility of misconnection is absolutely avoided, which may result in short circuit or even burn the meter. The device with high-contrast LCD screen, and the character in big size, which helps to obtain the best visual effects.

Product Features

  1. 1. Ingenious structure, easy to operate.

    A. hand held structure

    B. you should not disconnect the circuit or change the measurement range under 10mA-10A, 3V-500v.

    C. use high contrast LCD, character can be 25mm, the screen angle can be 700, to obtain the best visual effects

    D. the function and layout of the switch are reasonable, rotating can read the measuring voltage, current and phase.

    2. High resolution

    Adopt new type patent current clamp, current resolution up to 0.1mA; voltage resolution up to 0.1V.

    3. Low power consumption

    This product with micro power consumption design and with the function of testing the voltage of battery

Technical parameters

Intrinsic Error

Reference Working Conditions Temperature (23±5)℃
Hunidity (45~75)%RH
Wave forms of measured signal sine wave,β=0.02
Frequency of measured signal (50±0.2)Hz
Position of Measured current carrying conductor in the nipper jaw Optional position
Amplitude range of measured signal when measuring phase 100~220V,0.5~1.5A
External reference frequency electromagnetic interference Should be avoided

Limits of Intrinsic Error

1 AC Voltage

Table 1:Measurement Error of AC Voltage
Measure range Resolution Limits of intrinsic error
20V 0.01V ±(0.3%RD+0.2% Range)
200V 0.1V ±(0.3%RD+0.2% Range)
500V 1V ±(0.3%RD+0.2% Range)

Input Impedance:2MΩ for all the measure range .

Voltage input impedance of phase testing: >500KΩ

2 Alternating current

Table 2:Measurement Error of alternating current
Measure range Resolution Limits of intrinsic error
200mA 0.1mA ±(0.3%RD+0.2)
2A 1mA
10A 10mA

3 Phases

U-U,U-I,I-I (see Table 3)

Table 3: Measurement Error of Power-frequency Phase
Range Resolution Limits of intrinsic error
0~360° ±2°

Impedance of input voltage loop when measuring phase of U1-U2:40KΩ

Operating error

Rated Working Conditions Temperature (0~40)℃
Humidity (20~80)% RH
Wave forms of measured signal Sine wave,β=0.05
Frequency of measured signal (50±0.5)Hz
Position of Measured current carrying conductor in the nipper jaw Optional position.
Amplitude range of measured signal when measuring phase Phase U1-U2:30V~500V
Phase I1-I2:10mA~10.00A
Phase U1-I2 or I1-U2:10V~500V,10mA~10.00A
External reference frequency electromagnetic interference should be avoided
Limits of Rated Working Error Under the conditions described in 1, the limits of the rated operating error will not exceed twice of the limits of intrinsic error.

Other technical features

Display three and half
Sampling rate 3 times per second
Power supply Single 9V laminated cell,current of power is less than 5mA
Dimensions Meter shell 192×95×55mm3
Clamp shell 140×42×20mm3
Nipper jaw Φ7mm×9mm
Weight Meter body 280g
Measuring clamps 2×200g
Storage Conditions Temperature -10℃~50℃

Product Tags:

Double Clamp Digital Phase Meter

      

Voltammeter Digital Phase Meter

      

CE Voltammeter Phase Tester

      
China CE Hand Held Voltammeter Double Clamp Digital Phase Meter wholesale

CE Hand Held Voltammeter Double Clamp Digital Phase Meter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Wuhan Rising Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)